BayRail® signalling cables

acc. to the specification of Deutsche Bahn AG

core stranded, filled, (H115) / (H145), acc. toDB TL 416.0113

A-2YOF(L)2YB2Y

…x1x0,9      |      …x1x1,4     |      …x1x1,8


AJ-2YOF(L)2YDB2Y

…x1x0,9     |      …x1x1,4     |      …x1x1,8

stranded in cores, filled, (H95) acc. to DB TL 416.0114

A-2YOF(L)2YB2Y

…x1x1,4     |      …x1x1,8


AJ-2YOF(L)2YDB2Y

…x1x1,4     |     …x1x1,8

A-2Y(L)2YB2Y

…x4x0,9     |     …x4x1,4


AJ-2Y(L)2YDB2Y

…x4x0,9     |     …x4x1,4

Signalling cable in combination of stranding in cores – and stranding in quads, acc. to DB TL 416.0118

A-2Y(L)2Y2YV / A-2Y(L)2Y2YB2Y / AJ-2Y(L)2Y2YDB2Y

…x1x0,9/1,4/1,8

Rail foot cable-, PZB -,LZB-, Balise cable, Tusi®

TUSI® Specified as data cable for OLSP systems, based on DIN VDE 0816/part 1/2.88 and Dlk 1.013.151

Tusi® Tunnel safety cable …x2x0,8

Signalling cable, halogen free, flame retardant

acc. to Bayka-specification, an based on DB Dlk 1.013.102y

A-HHV…

…x1x0,9     |     …x1x1,4    |    …x1x1,8

acc. to Bayka-specification, based on DB Dlk 1.013.102y

A-HHBH

…x1x0,9    |    …x1x1,4    |    …x1x1,8

acc. to Bayka-specification, based on DB Dlk 1.013.201y

A-H(L)HV …x4x0,9

A-H(St)HV

…x4x0,9     |    …x4x1,4

acc. to Bayka-specification, based on DB Dlk 1.013.201y

A-H(L)HBH

…x4x0,9    |    …x4x1,4

Telecommunication cables for railways

A-02YSF(L)2Y…StIII

…x2x0,6    |    …x2x0,8

AJ-02YSF(L)2Y…StIII …x2x0,8

BayCom® Telecommunication cable St I, for laying in soil, acc. to DB TL 416.0530 (replaces Arcor TNP02)

A-02YSTF(L)2YV composite layer sheath

AJ-02YSTF(L)2YDB2Y anti-inductive protection

A-02YSTF(L)2YB2Y / A-02YSTF(L)2Y(SR)2Y steel tape armouring

Geeignet als Ersatz für papierisolierte Weitverkehrskabel nach Dlk 1.01.106 (auch Abschnittsweise): PDF-Download

Fibre optical cables for railways

International railway cables

French Signalling cable, acc. to SNCF CT 445

ZPGU …px1mm²      |       ZPAU …px1mm²     |      ZPFU …px1mm²     |      ZCO3 4qx1mm² (4qx1,13mm)

cable for control center, acc. to SBB 3001.82.1000

BayRail® SW-CLT    …x4x1,0      |      …x4x1,5     |    …x4x2,2


BayRail® Signalling cable, quad stranded, halogen free, flame retardant, low smoke, acc. to Bayka-specification, based on DB Dlk 1.013.201y

A-H(L)HV      …x4x0,9

A-H(St)HV    …x4x0,9      |     …x4x1,4


BayRail® Signalling cable, quad stranded, armoured, halogen free, flame retardant, low smoke, acc. to Bayka-specification, based on DB Dlk 1.013.201y

A-H(L)HBH   …x4x0,9     |     …x4x1,4


BayRail® Balise cable, acc. to SBB 3001.52.2000

PE-ALT-CLT …x4x1,53

BayRail® signalling cable acc. to specification of RENFE/ADIF, acc. to E. T. 03.365.051.6

CCPSSP-H     |     CCPSSP-P     |     CCPSSP-PI     |     CCPSSP-X

CCTSST-H     |     CCTSST-P     |     CCTSST-PI     |     CCTSST-X

EAPSP-H       |     EAPSP-P        |     EAPSP-PI       |     EAPSP-X

EATST-H       |     EATST-P        |     EATST-PI        |     EATST-X

Stranded in cores and with PVC-sheath, acc. to DB Dlk 1.013.102y

A-2YY     …x1x0,9     |     …x1x1,4     |     …x1x1,8


Stranded in cores, armoured and with PVC-sheath, acc. to DB Dlk 1.013.102y

A-2YYbY    …x1x0,9     |     …x1x1,4     |     …x1x1,8


Stranded in cores, anti-inductive protection and with PVC-sheath, acc. to DB Dlk 1.013.102y

AJ-2Y(St)YbY    …x1x0,9     |     …x1x1,4     |     …x1x1,8


Quad stranded, screened, armoured and with PVC-sheath, acc. to DB Dlk 1.013.201y

A-2Y(St)YbY    …x4x0,9     |     …x4x1,4


Quad stranded, with anti-inductive protection and PVC-sheath, acc. to DB Dlk 1.013.201y

AJ-2Y(St)YbY     …x4x0,9     |     …x4x1,4

Technical Information, Tables and Data

Here you will find general information, technical tables for electrical and mechanical characteristics, material tables, cable designation codes and further details about cables and wires.

Pictograms

technical information on power cables
VDE, RoHS / REACH, CE, pictograms